• ghterve@lemmy.world
    link
    fedilink
    arrow-up
    176
    arrow-down
    2
    ·
    edit-2
    2 months ago

    When this was posted on Reddit recently, someone claimed this was caused by a fallen power line that made contact with a gas line. So, power flowing into the house through gas pipe and back out through equipment grounds, heating up lower resistance gas pipes in the process.

    Photo reportedly taken by fire fighters or gas company employees.

    Edit: I meant to type higher resistance…

    • Thorry84@feddit.nl
      link
      fedilink
      arrow-up
      40
      arrow-down
      8
      ·
      edit-2
      2 months ago

      This makes no sense at all.

      Why would only these two specific pipes get hot, so hot to glow, but not the other lines connected to it? And not the fittings around it? It’s all copper, so even if the power itself doesn’t heat them up, why would being connected to an extremely hot pipe heat it up. Since it’s you know copper and being good at transferring heat is what it’s known for.

      And why would the lower resistance part be the part that get hottest? Low resistance means less loss, so those parts would in fact be the coldest of all.

      Plus thin walled copper pipes can’t get so hot they glow without melting or at the very least lose all structural integrity and break.

      And a downed power line with a short to ground would almost immediately turn off. It’s when there isn’t a direct line to ground those things are dangerous. As soon as it shorts, it gets turned off at the source to prevent further damage, fire and not cause issues upstream.

      Either it’s Photoshop or someone has wrapped led lighting around some pipes.

      • friendlycheese@lemmy.world
        link
        fedilink
        arrow-up
        57
        ·
        2 months ago

        Both of the lines that are lit up are flexible aluminum couplings. They’re required in some areas as the final connections to the appliances. They’re in line with cast iron gas pipe and fittings. They are much more thin and way better at conducting heat.

        Source: former HVAC tech

        • Thorry84@feddit.nl
          link
          fedilink
          arrow-up
          10
          ·
          edit-2
          2 months ago

          Thanks for the clarification, pipes look like copper but might be cast iron.

          Still doesn’t fit with the explanation, aluminum has more resistance than copper, but not that much more. The resistance of cast iron is an order of magnitude higher than aluminum. So it would still be the lowest resistance in the circuit and thus the coolest part.

          And cast iron is pretty good at conducting heat. Not as good as copper or aluminum, but still pretty good. We’ve been using the material to make pans and pots for cooking because of it’s thermal properties. So the heat wouldn’t just stop at the fitting, but continue on at least some ways.

          Moreover it’s physically impossible to get aluminum hot enough to glow like this and still keep its shape. It melts at 600 degrees C, well below the point where something gets red hot, let alone yellow like this. If the aluminum were to be this hot, it would be in a puddle and at risk of burning.

          • ghterve@lemmy.world
            link
            fedilink
            arrow-up
            8
            ·
            edit-2
            2 months ago

            Sorry, I meant to type higher resistance. On my water heater, the equivalent part that is glowing in the picture is a really thin flexible corrugated gas pipe that surely can carry much much less current than the iron gas pipe feeding it before it went really high resistance. I could totally see it glowing like this with enough current. But if it is aluminum (not sure if it is), what you said makes sense.

            My gas pipe to the house comes out of the ground inside a plastic protective pipe sleeve, so I can imagine it possibly not having enough of a low resistance path to earth to trip one of the cutout fuses on the primary distribution line. Granted, mine also has a big ground wire bonding it to the house ground, which I would think would help here…

            /shrug I was just sharing what I read. It was supposedly the explanation as to why local breakers on the house didn’t trip.

          • YerbaYerba@lemm.ee
            link
            fedilink
            arrow-up
            8
            ·
            2 months ago

            The flexible pipes are normally stainless steel. The main gas line is steel with thick walls so this seems plausible to me. Stainless steel has higher resistance than steel and is so much thinner.

  • nick@midwest.social
    link
    fedilink
    arrow-up
    125
    ·
    edit-2
    2 months ago

    This happens when the neutral goes out in a house. Usually the waterlines will handle it, but if the house has pex the ground will go through the gas lines.

    Especially if a high voltage line comes down on a gas meter for whatever reason.

    Definitely run away and call professional… everyone i guess.

    • AngryCommieKender@lemmy.world
      link
      fedilink
      arrow-up
      18
      ·
      2 months ago

      Would killing the main breaker at least prevent the heating of the pipes so that the expert isn’t walking into a potentially dangerous situation?

      • ghterve@lemmy.world
        link
        fedilink
        arrow-up
        19
        ·
        2 months ago

        I think in this case the power heating the pipes is not coming from this house’s electrical service, so killing the main breaker probably won’t help.

      • carpelbridgesyndrome@sh.itjust.works
        link
        fedilink
        English
        arrow-up
        10
        ·
        2 months ago

        I’m a little concerned killing the main breaker might result in a sudden temperature change that might fracture the gas line. Of course if you turn the gas off you might get fried.

      • Rai@lemmy.dbzer0.com
        link
        fedilink
        arrow-up
        9
        arrow-down
        1
        ·
        2 months ago

        I read that this happened due to a downed power line. Unfortunately, killing the main breaker would not do anything.

    • bobs_monkey@lemm.ee
      link
      fedilink
      arrow-up
      11
      ·
      2 months ago

      We found out a while ago that plumbing pipes aren’t the best way to ground a house for a variety of reasons, and this is why ufers (grounding to foundation steel) and ground rods are now the NEC standard. Also, this is why bonding wires are important as well. If the plumbing were bonded to a proper dwelling ground system, the current would find a direct path to ground and trip the responsible breaker, instead of using the gas lines as a big ass resistor and creating the light show we see here.

    • David_Eight@lemmy.world
      link
      fedilink
      arrow-up
      6
      ·
      2 months ago

      I’ve never seen pex running into a house from the street/ground. It’s always been copper up to the water meter at the very least and it’s code (in NJ at least) to put grounding wire there.

    • Anivia@feddit.org
      link
      fedilink
      arrow-up
      3
      ·
      2 months ago

      This would have also been prevented if the electrical install included an RCD. It would have tripped instantly when the neutral gets disconnected

      • bobs_monkey@lemm.ee
        link
        fedilink
        arrow-up
        1
        ·
        2 months ago

        Better yet to just have a bond to the gas and water pipes. In this instance, any current introduced to the plumbing has a direct connection to ground, which will allow current to flow freely and trip the breaker.

    • Asifall@lemmy.world
      link
      fedilink
      arrow-up
      1
      ·
      2 months ago

      Shouldn’t everything be grounded through the panel as well? I know I have a ground wire running out to a copper plate in the ground next to my house and my understanding was that if the neutral goes that would serve as the path to ground. Is this house missing that feature or am I wrong?

  • Jo Miran@lemmy.ml
    link
    fedilink
    arrow-up
    84
    ·
    edit-2
    2 months ago

    “Home is equipped with a 50 Gallon gas water heater upgraded with RGB lines for an extra 10 FPS.”

    • ayyy@sh.itjust.works
      link
      fedilink
      arrow-up
      57
      arrow-down
      3
      ·
      edit-2
      2 months ago

      Leave immediately and call 911 for an impending gas explosion. Tell them exactly what you saw, it will need to be disconnected somewhere very far away from the house. Aside from this being an obvious fake if you see a glowing pipe it’s the result of a deadly serious electrical fault that has bypassed at least 2 safety mechanisms that would otherwise prevent this catastrophic failure and at that point you really don’t even want to be touching the walls of the structure involved.

    • ouRKaoS@lemmy.today
      link
      fedilink
      arrow-up
      35
      ·
      2 months ago

      Run. That’s what I would do. Then probably call the fire department, the gas company, or an exorcist. Possibly all 3.

    • normalexit@lemmy.world
      link
      fedilink
      arrow-up
      12
      arrow-down
      1
      ·
      2 months ago

      Either turn off the gas if you can safely do it, or call your gas company so they can shut off the supply to your house.

  • werefreeatlast@lemmy.world
    link
    fedilink
    arrow-up
    33
    arrow-down
    1
    ·
    2 months ago

    So there’s an air leak upstream allowing a fire inside the gas line. And the house didn’t go up in flames I assume. Probably this situation would not end in a big explosion but rather just a house fire. Still pretty scary.

  • enkers@sh.itjust.works
    link
    fedilink
    arrow-up
    17
    ·
    2 months ago

    While it looks scary as fuck, wouldn’t it not actually explode unless the gas pipe melted through? There’s no oxygen in the fuel, so it can’t combust. I guess as the gas heats up, it’s also possible the for the tank or lines to spring a leak.

    Either way, I’d be nopeing out and calling emergency services.

      • enkers@sh.itjust.works
        link
        fedilink
        arrow-up
        23
        ·
        2 months ago

        I think you’re right. I was curious, so I looked it up.

        The melting point of copper is 1,085°C, and judging from this chart, its definitely getting close:

        metal color temp chart

        • JasonDJ@lemmy.zip
          link
          fedilink
          arrow-up
          4
          arrow-down
          1
          ·
          2 months ago

          You ever see gas hookups in the US?

          We use black pipe for most of the run. Cast Iron. The actual hookup itself is a flexible pipe…SS or Aluminum I think. Been a long time since I had gas. Sometimes they have like a rubbery-epoxy-ish coating but I assume that’s now quite gone and stinky.

          • enkers@sh.itjust.works
            link
            fedilink
            arrow-up
            1
            ·
            2 months ago

            Oh, huh. That’s interesting. I’m from the great white north, and our gas hookups are copper from what I’ve seen. If this is indeed iron, then the melting point would be higher: ~ 1,540°C.

            Interestingly that colour temperature chart is supposedly fairly consistent across different metals.

            • JasonDJ@lemmy.zip
              link
              fedilink
              arrow-up
              2
              arrow-down
              1
              ·
              2 months ago

              Tbh I don’t know why we don’t use copper. I imagine because it’s more difficult to fuck up threaded and doped connections as opposed to soldered ones.

          • Zannsolo@lemmy.world
            link
            fedilink
            arrow-up
            1
            ·
            2 months ago

            Def not cast iron, cast iron is used for waste pipes and it’s brittle you could never get threads on cast iron. It’s actually steel even if we call it black iron. A lot of newer houses will run solid pipe from the main to a central location and build a manifold with corrugated steal (flexible pipes) run to the terminal points.