Hello, we are making a thesis where we use MOSFETs as an alternative radiation detector. So to explain it, it works when the mosfet is irradiated with an external radiation source; its voltage threshold increases, which will be used to determine the radiation dose. I’m currently asking for help on how we measure the voltage threshold. BTW, we are using an n-channel MOSFET (model: IRFP250NPbF). Also in the datasheet provided by the manufacturer, it says here VGS(th)/Gate Threshold Voltage Min: 2.0 ––– Max: 4.0 V. There is a condition here with VDS = VGS, ID = 250 A. Does this mean that to measure the VGS, we need to first satisfy the conditions? To measure the voltage threshold, what node will we use to measure the VGS (th)? Is it at the drain to the source terminal or still at the gate to the source terminal? Feel free to share your thoughts, if you have any. I would also like to add that we have already tried to supply a voltage at the gate with respect to the source terminal. We use a 4 V supply voltage, and when we tried to measure the VDS (drain to source voltage), there was a voltage drop, so we’ve got a 3.5 V. Also, we are using an Arduino to measure its voltage and a multimeter for checking.

  • Lazyhotodogu@lemmy.world
    link
    fedilink
    English
    arrow-up
    1
    ·
    1 year ago

    Hello, I have already tried to apply a microampere current (around 40 μA) using only Ohm’s law. I used a 2V input and a resistor in series. However, the LM334z is not working, and I am unsure of the reason for its failure. Will using an input voltage and a resistor in series work just fine?

    I have also measured the Vgs, which reads at around 0.117 mV. What do you think about the measured Vgs? Technically, it should be around these values, right? Considering that there is a very small current.

    • blarbasaurus@lemmy.world
      link
      fedilink
      English
      arrow-up
      2
      ·
      1 year ago

      You will probably need to increase your voltage. I haven’t ever used the LM334, but it will need a minimum voltage across it. I don’t know if you are still using the IRFP250N, but if so it has a threshold somewhere between 2V and 4V for 250uA, so the threshold won’t be as high but it should be close. I would try using 5V if it’s fine with your setup.

      For the suitability of the resistor method, you should do the math on how a change in Vds will affect the current, and then calculate how much this variability in current will affect your readings. If this error/innacuracy is acceptable, then why not.

      • Lazyhotodogu@lemmy.world
        link
        fedilink
        English
        arrow-up
        1
        ·
        1 year ago

        I just want to ask some points:

        • Do you mean that to properly operate the LM334, we need to apply or reached the threshold voltage of the MOSFET which is around (2 and 4V)? But, i’ve tried to used it (LM334z) as a standalone and still it doesn’t work. maybe the LM334z is the problem hahaha *Regarding the resistor method, What do you think about the measured Vds, Vds=117mV (With an input current of 40uA)? i’m confused with the “how a change in Vds will affect the current” *Isn’t it Vds the parameter required for determining the dose? So if there is a constant current and resistance, how does the radiation affects the MOSFET? Will resistance or current increase upon irradiation leading to an increase in the measured Vds?